2–Event Messages
Informative Events
2-72 59060-07 D
Informative Events
Informative events are events that occur in the normal activities of a fabric. The
following lists the event ID and text of the message along with an explanation of
the message.
(I) (8200.0001) (mserver) (Hotreset is not permitted at this time, try again later)
Meaning: The switch was busy at the time of the attempted hot reset. Try the
hot reset again later.
(I) (8200.0002) (mserver) (Port: port_number) (Rejecting request from address FC_address,
inband management is disabled on port port_number)
Meaning: A Management Server command was received on a port that is
configured to refuse inband management requests.
(I) (8200.0100) (mserver) (Cannot map number_of_characters characters to Switch
Symbolic Name (max number_of_characters))
Meaning: The RIELN management server command was processed, and the
Interconnect Element Logical Name was registered. However, the
registered name is of greater length than the maximum length
allowed for the Switch Symbolic Name, so therefore the Switch
Symbolic Name was not changed to match the registered name.
(I) (8200.0101) (mserver) (Cannot map non-printable characters to Switch Symbolic Name)
Meaning: The RIELN management server command was processed, and the
Interconnect Element Logical Name was registered. However, the
registered name contains unprintable characters. These characters
are not allowed for the switch symbolic name, therefore the switch
symbolic name was not changed to match the registered name.
(I) (8200.0200) (mserver) (Rejecting request (GZM) for zone zone_name containing
unsupported alias member(s)
Meaning: The fabric zone server command GZM (Get Zone Member) was
rejected because the requested zone member was an alias that is
not defined in Fibre Channel General Services-3 (FC-GS-3).
(I) (8200.0201) (mserver) (Rejecting request command:command)
Meaning: A fabric zone server command was rejected for the reason detailed
in the message. This can be caused by two users attempting to
configure the switch or zoning database at the same time. Contact
your authorized maintenance provider if the reason for the failure is