TROUBLESHOOTING CHART

Problem

Possible Caus

Remedy

 

 

 

 

 

 

 

 

 

Poor reception

Weak signals from

Reposition radio for

 

distant stations

best reception.

 

 

 

 

Attenuator is in use

Check performance with

 

on weak signals.

and without attenuator

 

 

activated, use setting

 

 

with best reception.

 

 

 

 

Strong signal

Check performance with

 

overload from

and without attenuator

 

nearby

activated, use setting

 

transmitter(s)

with best reception.

 

 

 

Scanner will

AC or DC power

Check connection to AC

not power on

supply is not

or DC power source.

 

properly connected.

 

Dead batteries

Replace batteries.

 

Keypad lock is

Press FUNC LOCK to

The keypad

activated.

disable keypad lock.

 

 

The scanner may

See “Resetting /

does not work

need to be reset or

Initializing the Scanner”

 

 

initialized.

on Page 108.

 

 

 

Scanner will

Possible “birdie”

Tighten squelch, apply

not scan when

frequency

attenuator or lock out

SCAN is

programmed

the “birdie” frequency.

pressed.

The scanner may

See “Resetting /

 

 

need to be reset or

Initializing the Scanner”

 

initialized.

on Page 108.

 

No channels

Ensure that the scanner

 

programmed, or

has more than one

 

only one channel

channel programmed

 

programmed, or all

and enabled for

 

channels locked

scanning.

 

out

 

 

SQUELCH is not

Turn SQUELCH

 

adjusted properly.

clockwise until scanning

 

 

resumes.

 

 

 

107