systems operating in the VHF and UHF bands. To monitor these systems it is necessary to program the scanner with three additional parameters, the base frequency, step and offset.Ó

Follow these steps to program Motorola trunking frequencies in the VHF or UHF bands:

1.Press PGM, and then TRUNK to enter the ID program mode.2.Press FUNC and press (or hold) S or T to select the bank.3.Press MODE until Motorola appears in the display.4.Press FUNC then 2. The display indicatesBase Freq: 406.0000 Offset: 380 Step:25.0kHz

5.While B in Base blinks, if necessary, enter the desired Base frequency with the number keys and press ENTER. If it is incorrect, press the number keys again to set the base frequency.

6.While O in Offset blinks, if necessary, enter the offset number and press ENTER. If it is incorrect, then press the number keys again to set the frequency.

7.While S in Step blinks, repeatedly press S or T to select the step number, 5,

Ó HINTS Ó

Base frequency, step and offset vary for each individual UHF trunking system. You can get information about these frequencies for the trunking system you want to scan using trunkscanner.com, other Internet sources, or locally published guidebooks.

Systems with multiple channel ranges can be programmed using PC application software.

35