SAMPLING

8.

Length

Specifies the time after which sampling will stop.

• The Length setting is used only when Stop
Trigger= Beat or Time.
• The maximum value for Length depends on the
remaining amount of sampling memory.
9.
Pre Sample Time
Specifies how much time prior to the actual start of
sampling will be captured in the sample.
Range:
0
, 20, 40, 80, 160, 320, 640, 1000 ms
10.
Auto Divide
The Auto Divide function detects regions of silence
within the sample, and divides the sample into
several samples at these points.
Range:
Off
, On
11.
Gap Time
When Auto Divide=On, this parameter specifies the
length of the silent regions that will be detected.
Range:
0.5
, 1.0, 1.5, 2.0 sec

The Gap Time setting is used only when Auto
Divide=On.

12.

Auto Emphasis

Automatically pre-emphasis processes after
sampling.
Range:

Off

, On

13.

Auto Normalize

Automatically normalizes the level after sampling.
Range:

Off

, On

14.

Wave Memory

Indicates the amount of wave data stored in the
DIMM, both numerically and as a graph.

F-buttons

Sampling

Samples an external audio source. The SAMPLING
screen will appear.

Re-Sampling

Samples an internal audio source. The RESAMPLING
screen will appear.

Reset Peak

Clears the indicators of the peak hold in the Level
meters.

Start

Starts sampling.
If Start Trigger=Manual, sampling will begin
immediately. Otherwise, sampling will begin
according to the conditions specified by the Start
Trigger setting.

When Start Trigger = Level/Play/Pad

Cancel

Cancels the sampling operation.

Start

Manually starts sampling. A message of Now
Sampling... will appear.

When Start Trigger=Manual, or during sampling

Cancel

Cancels the sampling operation.

Stop

Stops sampling. The Sampling Result screen will then
appear.

Stop Trigger
parameter Value

Beat 1~

8

~20000
Time 000m01s~
000m02s
~
100m00s

Sampling type Screen that appears

Audio phrase/
patch

SAMPLING RESULT (AUDIO
PHRASE/PATCH) popup

(p.
357)
Sample

SAMPLING RESULT (SAM-
PLE) popup
(p. 359)