RuggedCom RS400 manual PPP Control, PPP Status, Local IP Address, Remote IP Address

Models: RS400

1 275
Download 275 pages 11.85 Kb
Page 227
Image 227

PPP over Modem

11.2.2 PPP Control

Figure 158: PPP Control Form

PPP Status

Synopsis: { Disabled, Enabled }

Default: Disabled

Whether PPP is disabled or enabled.

Local IP Address

Synopsis: ###.###.###.### where ### ranges from 0 to 255

Default: 192.168.1.1

This parameter specifies the IP address of the local side of the PPP link. Note that local and remote PPP addresses must be on the same subnet and that this subnet must be different from the management network address.

Remote IP Address

Synopsis: ###.###.###.### where ### ranges from 0 to 255

Default: 192.168.1.2

This parameter specifies the IP address of the remote side of the PPP link. Note that local and remote PPP addresses must be on the same subnet and that this subnet must be different from the management network address.

Subnet

Synopsis: ###.###.###.### where ### ranges from 0 to 255

Default: 255.255.255.0

This parameter specifies the IP subnet mask of this local and remote PPP addresses.