Ethernet Statistics

Default: 11800

A threshold for the sampled variable. When the current sampled variable value is greater than or equal to this threshold, and the value at the last sampling interval was less than this threshold, a single event will be generated. A single event will also be generated if the first sample after this record is created is greater than or equal to this threshold and the associated startup alarm is equal to 'rising'. After rising alarm is generated, another such event will not be generated until the sampled value falls below this threshold and reaches the value of FallingThreshold.

Falling Thr

Synopsis: 0 to 2147483647

Default: 11790

A threshold for the sampled variable. When the current sampled variable value is less than or equal to this threshold, and the value at the last sampling interval was greater than this threshold, a single event will be generated. A single event will also be generated if the first sample after this record is created is less than or equal to this threshold and the associated startup alarm is equal to 'falling'. After falling alarm is generated, another such event will not be generated until the sampled value rises above this threshold and reaches the value of RisingThreshold.

Value

Synopsis: 0 to 2147483647

The value of monitoring object during the last sampling period. The presentation of value depends of sample type ('absolute' or 'delta').

Type

Synopsis: { absolute, delta }

Default: delta

The method of sampling the selected variable and calculating the value to be compared against the thresholds. The value of sample type can be 'absolute' or 'delta'.

Interval

Synopsis: 0 to 2147483647

Default: 5

The number of seconds in over which the data is sampled and compared with the rising and falling thresholds.

Startup Alarm

Synopsis: { rising, falling, risingOrFalling }

Default: risingOrFalling

The alarm that may be sent when this record is first created if condition for raising alarm is met. The value of startup alarm can be 'rising', 'falling' or 'risingOrFalling'

Rising Event

Synopsis: 0 to 65535

Default: 1

The index of the event that is used when a falling threshold is crossed. If there is no corresponding entry in the Event Table, then no association exists. In particular, if this value is zero, no associated event will be generated.

Falling Event

Synopsis: 0 to 65535

Default: 1

The index of the event that is used when a rising threshold is crossed. If there is no

ROS™ v3.5

128

RS400

Page 128
Image 128
RuggedCom RS400 manual Falling Thr, Value, Startup Alarm, Rising Event, Falling Event