RuggedCom RS400 manual Mirrored Bits Form

Models: RS400

1 275
Download 275 pages 11.85 Kb
Page 82
Image 82

Serial Protocols

Figure 52: Mirrored Bits Form

Port

Synopsis: 1 to 4

Default: 1

The port number as seen on the front plate silkscreen of the switch.

Transport

Synopsis: { TCP, UDP }

Default: UDP

The network transport used to transport protocol data over IP network.

Loc Port

Synopsis: 1024 to 65535

Default: 61001

The local IP port to use when listening for an incoming connection or UDP data.

Rem Port

Synopsis: 1 to 65535

Default: 61000

The remote TCP port to use when placing an outgoing connection.

IP Address

Synopsis: ###.###.###.### where ### ranges from 0 to 255 or { <EMTY STRING> } Default:

For outgoing TCP connection (client) and UDP transport this is the remote IP address to communicate with.

For incoming TCP connection (server), this is the local interface IP address to listen to the local port for connection request. If empti string is configured, IP address of management interface is used.