RuggedCom RS400 manual Index, Requested Buckets, Granted Buckets, Interval

Models: RS400

1 275
Download 275 pages 11.85 Kb
Page 121
Image 121

Ethernet Statistics

Figure 84: RMON History Controls Form

Index

Synopsis: 1 to 65535

Default: 1

The index of this RMON History Control record.

Port

Synopsis: 1 to maximum port number

Default: 1

The port number as seen on the front plate silkscreen of the switch.

Requested Buckets

Synopsis: 1 to 4000

Default: 50

The maximum number of buckets requested for this RMON collection history group of statistics. The range is 1 to 4000. The default is 50.

Granted Buckets

Synopsis: 0 to 65535

The number of buckets granted for this RMON collection history. This field is not editable.

Interval

Synopsis: 1 to 3600

Default: 1800

The number of seconds in over which the data is sampled for each bucket. The range is 1 to 3600. The default is 1800.