Diagnostics

RS900 (v2, 40-00-0066), RS900 (v2, 40-00-0067) }

Shows the type, part number, and revision level of the hardware

12.5 Loading Factory Default Configuration

The Load Factory Default Configuration option will reset all configuration parameters to factory default values with the exception of parameters that affect basic connectivity and SNMP management. Specifically, configuration items in the following categories are not reset by this operation:

IP Interfaces

IP Gateways

SNMP Users

SNMP Security to Group Maps

SNMP Access

A prompt message will be displayed requesting confirmation of this action.

Figure 170: Load Factory Defaults Dialog

Note: It is possible to explicitly reset configuration items in the exceptional categories listed above to their default values by using the “sql” command. Please refer to the section entitled: “Upgrading Firmware and Managing Configurations”.

12.6 Resetting the Device

This operation will close all open Telnet connections and warm start the device after User has confirmed the reset operation from the Reset Device option.

RS400

243

ROS™ v3.5

Page 243
Image 243
RuggedCom RS400 manual Loading Factory Default Configuration, Resetting the Device, RS900 v2, 40-00-0066, RS900 v2