Operation Function

2) Water Supply function

2-1) When the ice tray is levelled again after ejecting ice, the water solenoid value will be controlled to supply water by time check basis. (See the “Time to supply water” Table)

3) Ice production

3-1) After 90 minutes pass from the water supply, the control board will check the temperature.

3-2) If the sensor reads the temperature lower than 19for more than 5 minutes, than the ice production process is completed.

4) Test function

In order to operate a test function, press the knob (Test Switch) for 1.5 second.

This function can be used to check a proper working, to clean the ice tray, and to adjust the water level in the ice tray.

4-1) This function only works when the ice tray is leveled and the ice full signal is cleared.

4-2) When the water line is connected, each process such as a water supply, ejection, and leveling, can be investigated by this button.

5) Ice off function

5-1) When the Ice off option is selected by Ice Type button, the ice making process will cease.

5-2) When the ice making process ceases, the final state will be the ice tray with supplied water.

5-3) When Cubed or Crushed option is selected again, the control board will check an accummlated time period. After making it 90 minutes and when the ice tray temperature is acceptable, ice ejection process will begin.

6) Functions when the freezer door is open

When the freeze door is open, all ice maker related processes will cease in order to minimize noise and to prevent ice from dispensing.

6-1) The ice tray stops moving regardless of the position.

6-2) The water supply process remains working as usual.

6-3) If the ice tray is in the middle of ice ejecting process, close the freezer for 30 seconds and check if the tray is leveled. If it is not leveled, it must be out of order.

9-10) Defrost Function

1)A defrost is determined based on the accumulated compressor on-time.

2)When the power is engaged for the first time, the defrost cycle for the freezer and the refrigerator will begin after 4 hours of the accumulated compressor on-time.

3)A defrost interval depends on the ambient temperature, the number of door openings, and the door open time.

4)A minimum interval is 6 hours and a maximum is 8 hours for the refrigerator, and 12 hours and 16 hours for the freezer, respectively.

5)The defrost heater on-time is determined by the defrost sensors as follow :

 

Refrigerator

Freezer

 

 

 

Heater ON

Below 50

-

 

 

 

Heater OFF

63

50

 

 

 

29

Page 29
Image 29
Samsung RS2666, RS2544, RS2622, RS2777 manual Water Supply function, Defrost Function, Heater on, Heater OFF