Circuit Descriptions

The step signals of DC 1112V will be generated periodically. If a sink signal outputs from IC4, DC 11-12V will be applied to the LED input terminal and sink the LED output terminal to 0V. Therefore, LED will be ON for 2 miliseconds.

2) Key Scan

The 6 step signals, Q6Q4 are applied to scan the 6 keys (buttons). When SW6 is pressed, the step signal from Q6 will be reduced to 5V and entered to the MICOM, then MICOM will match a corresponding function for SW6 key.

41

Page 41
Image 41
Samsung RS2666, RS2544, RS2622, RS2777 manual Key Scan