Diagnostics

11-5) If alarm sound

1) If “Ding-Dong” sounds continuously

Start

Yes

Freezer door MICOM No. 43, Fridge door MICOM No. 44

Regular voltage are 5V to Open : 0V to Close.

Isn’t the door opened minutely?

No

Isn’t water penetrated

into the door S/W?

YES

Is the input voltage of

main No. 43 and 44 changed at door-open,

door-close?

YES

Is the state of inserted connector

(CN30)being normal?

 

 

Remove causes after

 

 

comprehending the conditions of

 

NO

interference by door gasket, food etc.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Exchange the door S/W.

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Troubleshoot the breaking of wire and

 

 

bad door S/W.

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

Separate the door S/W and check if the measured value of unit is changed from 0 toaccording to S/W ON/OFF.

 

 

 

 

 

 

 

YES

 

Connector not inserted. Troubleshoot

 

 

 

 

poor contact.

Is the door S/W self-unit normal?

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

Exchange the door S/W.

 

 

 

 

 

 

Main PCB and door S/W are normal.

 

 

 

 

 

 

 

 

 

 

 

 

2) If “Beep” sounds continuously

Start

Didn’t you

select forced operation and forced

defrosting?

YES

Do buzzer

still sound after power-on

again?

YES

Check if there is any short parts due to

foreign matters and the test jumper part in the main-PCB.

Selected

 

Release the forced operation and

 

forced defrosting functions, or turn ON

NO

again after power OFF.

 

 

Main-PCB is normal

50

Page 50
Image 50
Samsung RS2622, RS2544, RS2666 If alarm sound, If Ding-Dong sounds continuously Start, If Beep sounds continuously Start