Circuit Descriptions

1-3) When the motor rpm is in 600700, it will stop automatically and it tries to resume after 10 seconds. If the motor is

not working properly after 5 time trials, it will rest for 10 minutes, then try to resume again. This process will be done continuously.

Note) If there is an abnormal situation for the motor, the self-diagnostics will show the corresponding LED segment.

10-9) EEPROM Circuit

EEPROM is semiconductor memory not to be erased. It can be used in the area of unstable electric power.

10-10) Option Circuit

There are a variety of models that have a different function. A different model can set up to use option circuit as shown.

10-11) Load Drive Circuit

D602

OPTION

XCoolSelect ZoneTM

ONo CoolSelect ZoneTM

1)The control of load in the system is accomplished by the main PCB.

2)Most of relays or SSRs can control the compressor, refrigerator/freezer defrost heater, and several option functions.

3)For the compressor, #18 pin of micro processor signals High (5V). This signal enters #5 pin of IC3 and #14 of output terminal which have base and collector functions of IC3 turns on and connects the GND. Relay 73 will be grounded through #14 of IC. Magnetic field will generate so that the second side of RY73 is activated and 115V is supplied to the compressor. On the other hands, if #18 of micro processor turns Low(0V), #5 of IC3, the current of RY 73 relay, and magnetic field will shut down in sequence. A contact point in secondary side of Relay 73 is off. Finally compressor will stop.