Diagnostics

11-6) If the panel PCB is not working normally:

1)Where lighting of the panel PCB is disabled, or only some lamps are disabled. Start

See Ref. 1: ‘View of the connection cabinet-door for the wire assembly’ in the manual.

Is the connector

NO

of upper hinge cover inserted

 

 

normally?

 

 

 

YES

 

Reinsert the connector. Troubleshoot

Is the main PCB

 

a poor contact.

NO

 

 

 

 

connector(CN50) inserted

 

 

 

 

 

 

normally?

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

Reinsert the connector in the main

 

 

PCB.

 

 

 

 

Is the connector of

 

 

 

NO

door panel PCB connector inserted

 

 

 

 

 

normally?

 

 

 

 

 

 

 

YES

 

Reinsert the connector. Troubleshoot

 

 

Is lighting operated

YES

a poor contact.

 

 

 

 

normally when the exchange of panel

PCB?

 

NO

Panel PCB itself has trouble.

 

1.Check the door wire of freezer – the disconnection of wire, short between wires.

2.Check the CABI wire of freezer – the disconnection of wire, short between wires.

3.Check the panel lighting circuit section within the main PCB for short open.

2)Where the Panel PCB key isn’t selected:

- The basic check way : If you is troubleshooting in the basic check method, then

YES

Is the locking lamp lit on?

NO

NO

Aren’t a key or more buttons

pressed continuously?

Recheck after the release of locking function.

 

 

 

 

 

 

Operated by

 

 

 

 

 

 

 

YES

Reassemble the PCB ass’y/Enforce

 

 

 

 

 

separation

 

 

Isn’t the PCB system

the cancellation of pressed keys.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

still operated by seperating of the

 

 

 

 

 

 

 

 

 

 

 

 

 

mechanism?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reassemble the PCB ass’y/Enforce

Refer to the description of

Is lighting

 

 

YES

the cancellation of pressed keys.

circuit operation in the

operated normally in the exchange

 

 

 

 

 

 

 

 

 

 

 

 

 

 

manual 10-6) Key scan

of panel

 

 

-PCB?

 

 

 

 

 

 

 

 

 

 

 

 

 

and display Circuit

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

selection’s, and measure

 

 

 

 

 

 

 

Panel PCB has trouble for itself.

the wave pattern.(page 40)

Is a periodic

 

 

NO

 

 

 

 

 

 

 

 

wave form outputted from the main

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PCB IC9?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

1. Replace the main PCB.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2. Check the short wires of CoolSelect

 

 

1. Check the door wire of freezer – check the breaking of wire, short between wires.

 

 

 

 

ZoneTM panel.

 

 

2. Check the CABI wire of freezer – check the breaking of wire, short between wires.

 

 

 

 

 

 

 

 

 

 

3. Check for Short/Open of the Panel Lighting Circuit section in the main PCB.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 