Diagnostics

11-2) If the compressor and cooling fan motor don’t work normally

Start

NO

Did 5 min pass after COMP. OFF?

YES

Check after a lapse of 5 min.

Does compressor work with forced operation?

YES

Did buzzer sound on forced operation?

 

 

NO

 

 

 

 

 

 

 

 

 

 

(Check certainly after forced start.)

 

 

Apply Ref.4

 

Is freezer sensor normal?

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is MICOM

No.18 High?(5V)

 

 

YES

 

 

 

 

 

 

 

 

Open and repair the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

connection.

 

 

 

 

 

 

 

 

 

 

Exchange MICOM and PCB.

 

 

 

 

 

 

 

 

 

 

 

 

 

Is the temp. sense

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of main PCB Normal?

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is the voltage of

IC03 pin No. 14 between 0-1V?

 

 

YES

Troubleshoot the

 

 

 

 

 

 

 

 

 

 

 

 

sensor and Exchange

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Exchange and repair IC03.

 

 

 

YES

Open and troubleshoot the

 

PCB.

 

(ULN2803)

 

 

 

 

 

NO

connection.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Apply Ref. 2

 

 

Is COMP relay normal?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

Exchange or troubleshoot

 

 

 

 

 

 

 

 

 

COMP relay.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

Is the contact of connector CN70 normal?

 

YES

 

 

 

 

 

Insert connector completely?

 

 

 

 

 

Is COMP assembly normal?

NO

 

 

 

 

 

 

 

 

 

 

 

 

YES

Exchange and repair COMP.

assembly.

Normal

47

Page 47
Image 47