Appendix Ⅰ(Reference for circuit diagnostics)
Ref.1) Wire connector on the cabinet door.
Ref. 2) How to check relay failure
Disconnect the connector of the main PCB
CN70 and CN71, then check the follows :
1. Measure the voltage at both terminals of a coil and
determine if the relay is working.
2. Measure the voltage at both terminals of a trigger and
determine if SSR is working.
3. Measure the resistance at both terminals of a load
contact, and determine if there is an error in voltages of coil and trigger.
Note) NC
C
Div. of contact | Voltage at both terminal of coil and trigger | Both terminals of contact | Resistance value |
| |
|
|
|
|
|
|
DC 12V (Working Condition) | Between C and NO | 0Ω (Short) |
| ||
|
|
|
|
| |
| Between C and NC | ∞Ω (Open) |
|
| |
terminal |
|
| |||
|
|
|
|
| |
DC 0V (Stop Condition) | Between C and NO | ∞Ω (Open) |
|
| |
Relay |
| ||||
|
|
|
|
| |
|
| Between C and NC | 0Ω (Short) |
| |
|
|
|
|
| |
∼ DC 12V (load working condition) | Betweenbothterminalsofcontact | 0Ω (Short) |
| ||
terminal |
|
|
|
|
|
∼DC 0V (load stop condition) | Betweenbothterminalsofcontact | ∞Ω (Open) |
|
| |
Relay |
| ||||
SSR | ∼DC 12V (load working condition) | Betweenbothterminalsofcontact | About |
| |
∼DC 0V (load stop condition) | Betweenbothterminalsofcontact | ∞Ω (Open) |
|
| |
|
|