Diagnostics

11-8) If CoolSelect ZoneTM isn’t operated normally (RS2555, RS2577)

1) If the lamp of CoolSelect ZoneTM is not lit.

Start

Is the connector of

NO

CoolSelect ZoneTM inserted correctly

 

 

in the refrigerator?

 

 

 

 

 

 

 

 

 

 

 

YES

 

Reinsert the connector; troubleshoot

 

 

 

 

Is the connector of main

NO

a bad contact.

 

 

 

 

 

 

PCB (CN51) inserted correctly?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

Reinsert the connector in the main

 

 

 

 

Is the connector of

NO

PCB.

 

 

 

 

CoolSelect ZoneTM panel PCB

 

 

 

 

 

 

 

 

 

inserted ?

 

 

 

 

 

 

If the Panel key isn’ t selected:

 

 

 

 

Reinsert the connector; troubleshoot

 

 

YES

 

 

 

 

 

Is lighting operated

YES

a bad contact.

 

 

 

 

normally in the exchange of CoolSelect Zone

TM

 

 

 

 

 

 

 

 

panel PCB?

 

 

 

 

 

 

NO

1.Check the wires of CoolSelect ZoneTM– check the disconnection of wire, short between wires.

2.Check the Lighting Circuit of CoolSelect ZoneTM panel in the main PCB for Short/Open.

3.Check the main PCB of CoolSelect ZoneTM assembly for Short; the wire assembly state between the panel and main PCB.

Panel PCB has trouble for itself.

2)If the Panel PCB key isn’t selected:

-The basic method is applied to check – if you fail in troubleshooting after above the execution, then

NO

Aren’t a key or more pressed

continuously?

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

Reassemble the PCB ass’y/Enforce

 

 

 

 

 

 

 

 

Isn’t the PCB system

 

 

the cancellation of pressed keys

 

 

 

 

 

 

 

 

still operated by separation?

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

Reassemble the PCB asswmbly and

 

 

 

 

 

 

 

 

Is lighting operated

YES

 

Enforce the cancellation of pressed keys

 

 

 

 

 

 

 

 

 

 

 

 

normally after the exchange of

 

 

 

 

 

 

 

 

 

 

 

 

panel-

PCB?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

Refer to 8-7) CoolSelect Zone TM,

 

 

 

 

Panel PCB has trouble for itself.

 

 

 

 

 

Is a periodical wave

NO

 

 

 

Panel Circuit and measure the

 

 

 

form outputted from the main

 

 

 

 

 

 

 

 

wave form.

PCB

 

IC9?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

1. Replace the main PCB.

 

 

 

 

 

 

 

2. Check the wire shorts of CoolSelect

 

1. Check the wires of CoolSelect ZoneTM – check the disconnection of wire, short between wires.

 

ZoneTM panel.

 

 

 

 

2.Check Short/Open the Lighting Circuit section of CoolSelect ZoneTM panel in the main PCB.

3.Check the short of main PCB in CoolSelect ZoneTM . Check the wire assembly

54

Page 54
Image 54
Samsung RS2622 If CoolSelect ZoneTM isn’t operated normally RS2555, RS2577, If the Panel PCB key isn’t selected, Wave form