Circuit Descriptions

Note)

1) F-DEF-sensor and Bimetal work in parallel.

2) At the first power on, an open error (5V input to MICOM) can be detected by self-diagnostics. A short error will be ignored.

3) In self-diagnostics during a normal operation, only an open error can be detected.

4) The F-DEF heater will be off at the set temperature after the bimetal is off.

10-6) Key Scan and Display Circuit

Power Freeze

Freezer Temp.

Ice Type

Power Cool

Fridge Temp.

Child Lock

1) Key Scan and display operation.

The model uses a decorder IC which 4 inputs and 9 outputs. If the IC 9 decorder (TC4028BP) receivesd signals from MICOM pins (36), an output signal per 2 miliseconds comes out from Q3, Q41, Q8, Q6, Q9, Q7, Q0, Q2, and Q4 pin in sequence. This signal enters to a driver IC input terminal of the CoolSelect ZoneTM PCB and IC5 (TD 62783AP), then approximate 11V peaks will generate from an output terminal as shown on the next page.

40

Page 40
Image 40
Samsung RS2544 manual DEF-sensor and Bimetal work in parallel, Key Scan and Display Circuit, Key Scan and display operation