Diagnostics

11-4) If there is a trouble with self-diagnosis

-Error of sensor can be seen on the front display of refrigerator. If power is impressed to refrigerator first, an failure of sensor is found. The refrigerator will stop working and display(blink) the region of trouble-occurred sensor repetitively.

-Even if sensor has failure during the operation, the refrigerator will not stop working but can run the normal cooling operation because of being operated in the Emergency Operation mode. Therefore you’ re requested to use how to check self-diagnosis(at page 31) in the manual.

1) If the ambient sensor has trouble

Start

See Ref. 4 (descriptions of circuit operation, and how to check temperature sensor in the manual.)

Was the Main

PCB connector(CN31) inserted correctly?

YES

Is the ambient temperature

sensor normal?

YES

Is the input of voltage to

MICOM pin No. 63 normal?

YES

No trouble with PCB and temperature sensor.

Recheck the contact failure of connector.

NO

NO

NO

A bad contact or connector missing?

Exchange the temperature sensor.

Check the iced solder and

short of main-PCB.

2) If the temperature sensor of F and R room has trouble

See Ref.4 (descriptions of circuit operation, and how to check temperature sensor in the manual.)

For sensor resistance per temperature, make use of the resistance values from Ref. 4 and 5.

Start

Is the unit of

NO

Fridge’s temperature

 

sensor normal?

 

 

YES

 

 

 

Was the Main – PCB

NO

connector(CN30) inserted

 

correctly?

 

 

YES

 

 

 

Is the sequence of

NO

insertion of connector(CN30) wire identical to

 

the circuit diagram?

 

 

YES

 

 

 

NO

Is the input voltage to

 

MICOM pin No. 59 normal?

YES

No trouble with PCB and temperature sensor.

Recheck the connector for an error of contact.

Exchange the temperature sensor.

Troubleshoot a bad contact or missing of

connector.

Modify the wrong configuration of connector wire -in case of being not inserted or incorrectly inserted - to be coincided with the circuit diagram.

Check if the iced solder of main PCB is

short.

49

Page 49
Image 49
Samsung RS2666, RS2544, RS2622, RS2777 If there is a trouble with self-diagnosis, If the ambient sensor has trouble Start