Diagnostics

11-11) If Crushed Ice/Cubed Ice doesn’t work properly:

Start

The close condition on operation is subject to the freezer door.

NO

Is ice ejected?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Does ice in the ice tray exist ?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1) Check the ice-ejector S/W.

Do you see Ice Stop on the digital panel?

NO

 

 

 

 

2) Check the door S/W.

 

 

 

 

 

 

 

 

 

 

 

 

3) Check the ice moving motor.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4) Check the cut of wire in the Ice

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

moving Motor section.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1) Check the water hose for folding or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cancel Ice Stop, select

 

 

fastening.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the Cubed/Crushed ice.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2) Check the ice-water-way and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

What’s your selection

 

 

 

 

Crushed ice

 

 

 

 

 

 

 

 

 

solenoid value

between crushed and cubed?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3) Check the wires of ice-maker.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cubed ice

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is the Crushed Ice extracted

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cubed ice extracted

 

sufficiently?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is the cube ice ejected sufficiently?

 

 

 

NO

 

 

 

 

Normal operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

Normal operation

Does MICOM No. 25 turn 5V if

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Does MICOM No. 25 turn

 

 

 

 

NO

 

pressing Ice S/W?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

Failure of Main PCB and exchange it.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5V if pressing Ice S/W?

 

 

 

 

 

 

 

 

 

 

 

Does the voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

Failure of Main PCB. –Exchange it.

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of IC3 No. 18 turn 0V even in the ice

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

S/W

 

OFF?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Does IC3 No. 18 turn 0V if

 

 

 

 

 

 

 

NO

 

 

Failure of Main PCB(IC3) and

 

pressing Ice S/W?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

exchange it.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Measure both contact

 

 

YES

Failure of Main PCB(IC3) –

 

 

 

 

 

 

 

 

 

Measure both terminals of RY77

 

 

 

 

 

 

 

 

 

 

 

contact after the separation of CN70,

 

terminals of RY77 after the

 

 

 

exchange it.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CN71 connectors.

 

separation of CN70, CN71

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Does the contact

 

 

 

 

 

 

 

 

connectors.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

shelf of RY77 relay turn 0even in the

 

 

 

 

 

Does the

 

 

 

 

NO

 

power

 

OFF?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

contact shelf of RY77 relay turn 0if

 

 

 

 

 

 

NO

 

Failure of Main PCB – exchange.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pressing ICE S/W?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(The contact terminal of RY77

 

 

 

 

YES

Exchange of Main PCB(RY77

 

 

Main PCB is normal.

 

 

 

relay short failure.)

 

 

 

 

relay).

 

 

- - - Check other sections.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1) Check the wire between the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUGER motor and main

 

 

 

 

 

 

 

 

 

 

Main PCB is normal.

 

 

 

 

 

 

 

 

 

 

 

PCB.

 

 

 

 

 

 

 

 

 

 

- - - Necessary to check other sections.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1)Check the wire between terminals of the AUGER motor and main PCB.

2)Failure of cube solenoid itself, or bad contact of the connector.

57

Page 57
Image 57
Samsung RS2666, RS2544, RS2622, RS2777 manual If Crushed Ice/Cubed Ice doesn’t work properly