Operation Function

9-12) Sound Function

1) Sound function

1-1) To make sure a command input, whenever a button is pressed, a “ding-dong” sounds.

1-2) When two or more buttons are pressed simultaneously or if a wrong button is pressed, there is no sound.

2) Door Open Alarm

2-1) When the doors remain open for 2 minutes, there are 10 times beeps.

2-2) If the doors continue to remain open more than 2 minutes, the additional 10 beeps interval will change to 1 minute.

2-3) The beeps will cease immediately when the doors are closed.

9-13) Exhibition Function

This function is for a display purpose on the floor of show room or store.

1) Mode ON/OFF

1-1) For the exhibition mode, press Power Freeze and Freezer Temp. buttons simultaneously for 8 seconds until a “ding-dong” sounds.

1-2) Press the same time buttons again for 8 seconds to cancel this mode put with a “ding-dong” sound.

2) Operation

2-1) Most of the system function except the compressor operation are working properly.

2-2) There is no defrost cycle in this mode.

9-14) Self-Diagnostics Function

1) Self-Diagnostics in the initial Power ON

1-1)The control board performs a self diagnostics test within 1 second and check out the temperature sensors abilities. 1-2) If a sensor failure occurs, a corresponding LED segment will blink with a beep.

1-3) When a LED segment blinks, only the cancellation function (Press Power Freeze and Power Cool buttons simultaneously for 8 seconds) is acceptable.

1-4) After a replacement of bad sensor or a cancellation of this function, this self diagnostics will end.

2) Self-Diagnostics in the normal operation

2-1) To select this function, press Power Freeze and Power Cool buttons simultaneously for 8 seconds with an audible tone.

2-2) In the self diagnostic mode, only corresponding LED segments will be illuminated (see the check list on the next page)

2-3) After a 30 second illumination of error signal, the system will return to the normal operation.

31

Page 31
Image 31
Samsung RS2777, RS2544, RS2666 Sound Function, Beeps will cease immediately when the doors are closed, Exhibition Function