Diagnostics

11-3) If defrost function

Start

Is F, R defrosting sensor by

self-diagnosis normal?

NO

YES

NO

Is F, R Room defrosting heater normal?

Exchange and troubleshoot the

corresponding sensor.

See Ref. 3: ‘Check load’ in the manual.

Make decision on the basis of ref. 4 and 6 in the manual.

See test function in the manual.

NO

Recheck the corresponding sensor for an error if it fails in return.

Reference

If temp. of F, R defrosting sensor by the working of heater are over 50, 63

 

 

 

 

 

 

 

YES

 

Check temp. fuse,

 

 

 

 

breaking of heater wire, contact of

Is temp. of the defrosting

NO

wire and so on.

 

 

 

sensor below 23?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

Run forced operation for a

 

 

specified period.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Perform forced defrosting for F and

R room at a time.

Is power applied to the

NO

respective defrosting heaters?

 

 

YES

Does the system

return to cooling operation after heating

for a specified period of time?

YES

Normal

See ‘Load Drive Circuit section’ and Ref. 2: How to check failure of relay.

Recheck the connection

NO

terminal in Main PCB

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

Repair the connection terminal.

 

 

 

 

 

 

 

Check temp. fuse, breaking of heater wire, contact of wire, and so on.

Exchange or troubleshoot the failure relay or

exchange PCB ass’y.

48

Page 48
Image 48