LOW VOLTAGE DETECTOR S3F80P5_UM_ REV1.00
NOTES
1. A term of LVD is a symbol of parameter that means ‘Low Level Detect Voltage for Back-Up Mode’.
2. A term of LVD_FLAG is a symbol of parameter that means ‘Low Level Detect Voltage for Flag
Indicator’.
3. The voltage gaps (LVD_GAPn (n=1~4)) between LVD and LVD FLAGn(n=1~4) have ± 80mV distribution.
LVD and LVD FLAGn(n=1~4) are not overlapped
Symbol Min Typ Max Unit
LVD_GAP1 150 230 310 mV
LVD_GAP2 250 330 410 mV
LVD_GAP3 800 880 960 mV
LVD_GAP4 1000 1080 1160 mV
Symbol Min Typ Max Unit
GAP Between LVD_Flag1 and LVD_Flag2 50 100 150 mV
GAP Between LVD_Flag2 and LVD_Flag3 500 550 600 mV
GAP Between LVD_Flag3 and LVD_Flag4 150 200 250 mV
V
REF
V
IN
Resistor StringComparator
LVD
(BackupMode
/Reset)
Bias
V
DIV
Comparator
V
DIV_Flag1~4
Bias
LVDCON.0
(LVD Flag Bit)
STOP
BANDGAP
MUX
LVDSEL.7-.6
Figure 15-1. Low Voltage Detect (LVD) Block Diagram