DURESS MODE OUTPUT SETUP

You can specify the output time for Duress mode.

1.Press the F5 SETUP MENU button.

2.

Use the buttons 4 and 6

to move to the DURESS ALARM item and

7.DURESS ALARM

 

 

press ENT .

 

 

3.

You can make input when the prompt blinks.

D R

A R

T 1

T 2

B Z

0 0

0 0

0 0

0 0

0 0

 

 

 

Use the keypad to enter the time for each output operation and press ENT .

DR : Door relay output

7.DURESS ALARM

 

AR : Alarm relay output

 

 

 

 

 

 

T1 : TTL #1 output

D R

A R

T 1

T 2

B Z

T2 : TTL #2 output

_ 0

0 0

0 0

0 0

0 0

BZ : Buzzer output

 

 

 

 

 

MDuress Alarm must be enabled (See Page 36 for “Duress Mode”.)

The output time differs, depending on the time unit.

If the time unit is 0.1 (second), you can specify the value between 0.0 and 9.8 second; if set to 1 (second), you can specify between 0 and 98 seconds.

For the time unit, refer to the ‘Time Unit Setup’ under the advanced setup. (see page 50)

If you enter 99 for the value, the product stays in output mode until you change the setting regardless of the time unit.

ARM/DISARM OUTPUT SETUP

You can specify the output time for ARM/DISARM mode.

1.Press the F5 SETUP MENU button.

2.

Use the buttons

4 and

6 to move to the ARM/DISARM SET item

8.ARM/DISARM OUT

 

and press ENT .

 

 

 

 

 

 

 

 

 

 

3.

You can make input when the prompt blinks.

D R

A R

T 1

T 2

B Z

0 0

0 0

0 0

0 0

0 0

 

 

 

 

Use the keypad to enter the time for each output operation and press ENT .

DR : Door relay output

8.ARM/DISARM OUT

AR : Alarm relay output

 

 

 

 

 

T1 : TTL #1 output

D R

A R

T 1

T 2

B Z

T2 : TTL #2 output

_ 0

0 0

0 0

0 0

0 0

BZ : Buzzer output

 

 

 

 

 

MARM/DISARM must be enabled. (See Page 37 for “Arm/Disarm”.)

The output time differs, depending on the time unit.

If the time unit is 0.1 (second), you can specify the value between 0.0 and 9.8 second; if set to 1 (second), you can specify between 0 and 98 seconds.

For the time unit, refer to the ‘Time Unit Setup’ under the advanced setup. (see page 50)

If you enter 99 for the value, the product stays in output mode until you change the setting regardless of the time unit.

English _ 43

I/O TIME SETUP

Page 43
Image 43
Samsung SSA-S2100/EXP manual Duress Mode Output Setup, ARM/DISARM Output Setup