Samsung SSA-S2100/EXP manual Reader #1 Error Output Setup, Reader #1 ID Error Output Setup

Models: SSA-S2100/EXP

1 76
Download 76 pages 8.53 Kb
Page 46
Image 46

I/O time setup

READER #1 ERROR OUTPUT SETUP

READER #1 ID Error Output Setup

1.Press the F6 SETUP MENU button.

2. Use the buttons 4 and 6 to move to the RD1 ID ERROR item and press ENT .

3.You can make input when the prompt blinks.

If you enter ‘00’, no output setting is configured.

Use the keypad to enter the time for each output operation and press ENT . DR : Door relay output

AR : Alarm relay output

T1 : TTL #1 output

T2 : TTL #2 output

BZ : Buzzer output

5.RD1 ID ERROR

D R

A R

T 1

T 2

B Z

0 0

0 3

0 0

0 0

0 0

5.RD1 ID ERROR

 

D R

A R

T 1

T 2

B Z

_ 0

0 3

0 0

0 0

0 0

M

The output time differs, depending on the time unit.

 

If the time unit is 0.1 (second), you can specify the value between 0.0 and 9.8 second; if set to 1 (second), you can

 

specify between 0 and 98 seconds.

 

For the time unit, refer to the ‘Time Unit Setup’ under the advanced setup. (see page 50)

 

If you enter 99 for the value, the product stays in output mode until you change the setting regardless of the time

 

unit.

READER #1 Time Schedule Error Output Setup

1.Press the F6 SETUP MENU button.

2. Use the buttons 4 and 6 to move to the RD1 T/S ERROR item and

6.RD1 T/S ERROR

press ENT .

 

The operation time for each output is the same as in “READER #1 ID Error Output Setup” above.

MTime schedule must be configured before. (See Page 51 for “Time Schedule Setup”.)

READER #1 Antipassback Error Output Setup

D R

A R

T 1

T 2

B Z

0 0

0 3

0 0

0 0

0 0

1.Press the F6 SETUP MENU button.

2. Use the buttons 4 and 6 to move to the RD1 APB ERROR item and press ENT .

The operation time for each output is the same as in “READER #1 ID Error Output Setup” above.

MAPB mode must be enabled before. (See Page 51 for “AntiPassBack Mode”.)

7.RD1 APB ERROR

D R

A R

T 1

T 2

B Z

0 0

0 3

0 0

0 0

0 0

46_ I/O time setup

Page 46
Image 46
Samsung SSA-S2100/EXP manual Reader #1 Error Output Setup, Reader #1 ID Error Output Setup