Unit 3: Installation

 

 

 

SOFTWARE SPECIFICATIONS

 

 

Corresponding Protocol

TCP/IP

 

 

Network Layer

ARP, RARP, IP, ICMP

 

 

Session Layer

TCP, UDP

 

 

Application Layer

LPD, FTP, TELNET, BOOTP, DHCP

 

 

NOTE: Print data can be sent by LPR and FTP of TCP/IP and dedicated socket protocol. Printer status is obtainable by dedicated socket protocol.

NOTE: In the TCP/IP protocol enviroment, LPD and FTP are provided for printing; TELNET for variable setup; ARP, RARP, and BOOTP/DHCP for address setup.

LPD protocol complies with RFC1179 and handles the list of logical printer name as queue name such as lp, sjis, euc. In addition, a banner page can be printed by a proper setup.

When sending the job by LPR, the transmission order of data file/control file within the job will not affect print operation. In addition, if the banner page is specified, it will be added to each data file. Job deletion by LPR is not available.

FTP protocol complies with RFC959 and handles the list of logical printer name as a transfer directory. File transfer to this directory executes print operation. It is possible to specify ASCII(A), Binary(I) and TENEX(L8) as transfer mode - although the mode difference is dependent on the client. A banner page may be printed with a proper setup.

TELNET Complies with RFC854. This operation consists of interactive menu form and enables change and reference of internal setup, and to display status. To change the setup, enter “root” user and password at the time of login. Default of root pasword is set as null (linefeed only).

ACCESSORY (EXT) CONNECTOR PIN ASSIGNMENTS

DB-9

14 PIN

DIRECTION

SIGNAL DEFINITION

 

 

 

 

1

13

To Host

Vcc +/- 5V

 

 

 

Ribbon Near End - Goes high when the amount of ribbon on the supply spindle is

2

10

To Host

approximately 46 feet (14m). The output will be low when the ribbon is completely

 

 

 

out.

3

4

To Host

Error - Goes low when the printer detects an error condition.

4

7

To Printer

Reprint - Prints a duplicate of the last label of a print job when this signal is

received.

 

 

 

5

5

To Printer

Print Start - Prins a single label when this pin is pulled to ground. This signal must

be enabled to function by placing dipswitch DSW3-5 to the OFF position.

 

 

 

 

 

 

End Print - Is used to drive an applicator or other external device requiring

6

6

To Host

synchronization with the print cycle. Four types of output signals may be chosen

 

 

 

by using dipswitches DSW3-6 and DSW3-7.

7

1

To Host

Label Out - Goes low (0V) when a label error exists.

8

3

To Host

Ribbon Out - Goes low (0V) when ribbon supply is out.

9

2

Reference

Signal Ground.

 

8

To Printer

Isolated Power Source - for signal input.

 

9

To Host

Mode 1: High voltage on LCD is selected = online, print job waiting.

 

Mode 2: High voltage on LCD is selected = online. Goes low (0V) when offline.

 

 

 

 

11

 

Reserved.

 

12

To Host

+24V +/- 10% @ 2A - Power for external devices.

 

14

 

Frame Ground

 

 

 

 

NOTE: The signals on pins 1, 3, 4, 6, 9, and 10 each have an open collector output. These pins normally measure +.07V maximum when a true condition exists. If a false condition ocurrs, the voltage will drop to 0V. To achieve a signal level of +5V, you must add a 330 ohm, 1/4 watt, pull-up resistor between the open collector output pin and Vcc (pin 13) as illustrated. This will provide a signal level of +5V for a true condition and 0V when a false condition exists. The maximum voltage that can be applied to these pins is +50V and the maximum current they can sink is 500 milliamps.

CL408-412e Supplemental Manual

3-13

PN: 9001159A

Page 28
Image 28
SATO CL408-412e manual Software Specifications, Accessory EXT Connector PIN Assignments, Direction Signal Definition