SATO CL408-412e manual Function, DSW1, Configuration, Description

Models: CL408-412e

1 98
Download 98 pages 5.83 Kb
Page 39
Image 39

 

 

 

 

 

 

 

 

Unit 4: Printer Configuration

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DSW1 FUNCTION DESCRIPTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FUNCTION

 

 

 

 

 

 

DESCRIPTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Data Bit

 

 

 

Sets the printer to receive either 7 or 8 bits of data for each byte transmitted.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parity

 

 

 

Selects the type of parity used for error detection.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stop Bit

 

 

 

Selects the number of stop bits to end each byte transmission.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Baud Rate

 

 

 

Select the data rate (bps) for the RS232 port.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Protocol

 

 

 

Selects the flow control and status reporting protocols.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DSW2 DEFAULT SETTINGS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-1

 

 

2-2

 

2-3

 

2-4

 

2-5

 

2-6

 

2-7

 

2-8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

OFF

 

OFF

 

 

OFF

 

OFF

 

OFF

 

OFF

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DSW2 CONFIGURATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DSW1

 

 

FUNCTION

 

 

SETTING

 

 

CONFIGURATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-1

 

Reserved

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-2

 

Media Sensor Selection

 

 

OFF

Gap Sensor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

Eye-Mark Sensor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-3

 

Head Check

 

 

 

 

OFF

Head Check Disabled

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

Head Check Enabled

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-4

 

Hex Dump

 

 

 

 

OFF

Hex Dump Disabled.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

Hex Dump Enabled

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-5

 

Multi-Job Receive Buffer

 

 

OFF

Single Job Receive Buffer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

Multi-Job Receive Buffer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-6

 

Firmware Download

 

 

 

 

OFF

Disabled

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

Enabled

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-7

 

Protocol Code

 

 

 

 

OFF

Standard Protocol Mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

Non-Standard Protocol Mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-8

 

Operational Mode

 

 

 

 

OFF

Normal Operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

Emulation Mode for Original M8400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DSW2 FUNCTION DESCRIPTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FUNCTION

 

 

 

 

 

 

DESCRIPTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Media Sensor Selection

 

Selects between a Gap or Eye-Mark detector.

 

 

 

 

 

 

 

 

 

Head Check

 

When enabled, will check for malfunctioning head elements.

 

 

 

 

 

 

 

 

 

 

Hex Dump

 

 

 

 

Allows hexadecimal printing of all data received to the print buffer.

 

 

 

 

Multi-Job Receive Buffer

 

Allows to continuously receive print jobs while compiling and printing other jobs.

 

 

 

 

Firmware Download

 

Places printer in mode for downloading software into flash ROM.

 

 

 

 

 

 

 

Protocol Code

 

Selects the command codes used for protocol control.

 

 

 

 

 

 

 

 

 

 

 

Operational Mode

 

Normal mode or for original M8400.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CL408-412e Supplemental Manual

4-4

PN: 9001159A

Page 39