Seagate DL585 manual Removing a Dimm

Models: DL585

1 86
Download 86 pages 32.8 Kb
Page 25
Image 25

Figure 16 Four DIMM slots

Table 5 Processor memory board memory banks with four DIMM slots

Slot

Bank

 

 

5–6

Bank 1

 

 

7–8

Bank 2

 

 

Removing a DIMM

1.Power down the server. See “Powering down the server” earlier in this chapter.

2.Extend the server from the rack. See “Extending the server from the rack” earlier in this chapter.

3.Remove the access panel. See “Removing the access panel” earlier in this chapter.

4.Remove the processor memory board. See “Processor memory boards” earlier in this chapter.

5.Remove the DIMM.

Figure 17 Removing a DIMM

IMPORTANT: Be sure all DIMM retention clips are in the closed/locked position before reinstalling processor memory board into the system.

Reverse the removal steps to install a DIMM.

Removal and replacement procedures 25