Seagate DL585 manual Hot-plug Scsi hard drive LED combinations

Models: DL585

1 86
Download 86 pages 32.8 Kb
Page 62
Image 62

Table 14

Hot-plug SCSI hard drive LEDs

Item

Description

Status

 

 

 

3

Fault status

On = Drive failure

 

 

Flashing = Fault-process activity

 

 

Off = No fault-process activity

 

 

 

Table 15 Hot-plug SCSI hard drive LED combinations

Activity LED

Online LED

Fault LED

Status

 

 

 

 

On

Off

Off

Do not remove the drive. Removing a drive during this process will

 

 

 

cause data loss.

 

 

 

The drive is being accessed and is not configured as part of an

 

 

 

array.

 

 

 

 

On

Flashing

Off

Do not remove the drive. Removing a drive during this process will

 

 

 

cause data loss.

 

 

 

The drive is rebuilding or undergoing capacity expansion.

 

 

 

 

Flashing

Flashing

Flashing

Do not remove the drive. Removing a drive during this process will

 

 

 

cause data loss.

 

 

 

The drive is part of an array being selected by the Array

 

 

 

Configuration Utility, or the Options ROMPaq is upgrading the drive.

 

 

 

 

Off

Off

Off

OK to replace the drive online if a predictive failure alert is received

 

 

 

and the drive is attached to an array controller.

 

 

 

The drive is not configured as part of an array.

 

 

 

-Or-

 

 

 

If this drive is part of an array, then a powered-on controller is not

 

 

 

accessing the drive.

 

 

 

-Or-

 

 

 

The drive is configured as an online spare.

 

 

 

 

Off

Off

On

OK to replace the drive online.

 

 

 

The drive has failed and has been placed offline.

 

 

 

 

Off

On

Off

OK to replace the drive online if a predictive failure alert is received,

 

 

 

provided that the array is configured for fault tolerance and all other

 

 

 

drives in the array are online.

 

 

 

The drive is online and configured as part of an array.

 

 

 

 

On or flashing

On

Off

Do not remove the drive. Removing a drive during this process will

 

 

 

cause data loss.

 

 

 

The drive is online and being accessed.

 

 

 

 

Server component identification 62