Table 14 |
| |
Item | Description | Status |
|
|
|
3 | Fault status | On = Drive failure |
|
| Flashing = |
|
| Off = No |
|
|
|
Table 15 Hot-plug SCSI hard drive LED combinations
Activity LED | Online LED | Fault LED | Status |
|
|
|
|
On | Off | Off | Do not remove the drive. Removing a drive during this process will |
|
|
| cause data loss. |
|
|
| The drive is being accessed and is not configured as part of an |
|
|
| array. |
|
|
|
|
On | Flashing | Off | Do not remove the drive. Removing a drive during this process will |
|
|
| cause data loss. |
|
|
| The drive is rebuilding or undergoing capacity expansion. |
|
|
|
|
Flashing | Flashing | Flashing | Do not remove the drive. Removing a drive during this process will |
|
|
| cause data loss. |
|
|
| The drive is part of an array being selected by the Array |
|
|
| Configuration Utility, or the Options ROMPaq is upgrading the drive. |
|
|
|
|
Off | Off | Off | OK to replace the drive online if a predictive failure alert is received |
|
|
| and the drive is attached to an array controller. |
|
|
| The drive is not configured as part of an array. |
|
|
| |
|
|
| If this drive is part of an array, then a |
|
|
| accessing the drive. |
|
|
| |
|
|
| The drive is configured as an online spare. |
|
|
|
|
Off | Off | On | OK to replace the drive online. |
|
|
| The drive has failed and has been placed offline. |
|
|
|
|
Off | On | Off | OK to replace the drive online if a predictive failure alert is received, |
|
|
| provided that the array is configured for fault tolerance and all other |
|
|
| drives in the array are online. |
|
|
| The drive is online and configured as part of an array. |
|
|
|
|
On or flashing | On | Off | Do not remove the drive. Removing a drive during this process will |
|
|
| cause data loss. |
|
|
| The drive is online and being accessed. |
|
|
|
|
Server component identification 62