Table 13

Quickfind diagnostic display LEDs

 

Item

Description

Status

Action

 

 

 

 

7

I/O power fault

Off = Normal

A power fault on the system I/O board occurred. If the

 

 

On = Attention required

problem persists, replace the system I/O board.

 

 

 

 

8

Therm trip

Off = Normal

The server experienced a thermal shutdown.

 

 

On = Attention required

If one of the CPU thermal LEDs is amber, that CPU

 

 

 

experienced an overtemperature condition.

 

 

 

Be sure that the processor heatsink is properly attached. For

 

 

 

more information, see Chapter 5, “Troubleshooting.”

 

 

 

Be sure that no 1.7-inch DIMMs are installed that prevent

 

 

 

airflow across the processor heatsink.

 

 

 

Be sure that the correct DIMMs (1.2 inches tall) are installed.

 

 

 

Be sure that all fans are installed and working properly.

 

 

 

 

9

SCSI interlock

Off = Normal

Be sure that the SCSI backplane is installed properly.

 

 

On = Attention required

 

 

 

 

 

10

Power supply 1

Off = Normal

Look at the LEDs on the front of the power supply and take

 

 

On = Attention required

the appropriate action.

 

 

 

 

11

Power supply 2

Off = Normal

Look at the LEDs on the front of the power supply and take

 

 

On = Attention required

the appropriate action.

 

 

 

 

12

Bus error

Off = Normal

A bus error occurred.

 

 

On = Attention required

The error might have been caused by one of the adapter

 

 

 

cards on this bus (see amber LEDs for which slots might have

caused the error).

If problem persists, remove or replace one or both of the cards.

Hot-plug SCSI hard drives

Figure 56 Hot-plug SCSI hard drive LEDs

Table 14

Hot-plug SCSI hard drive LEDs

Item

Description

Status

 

 

 

1

Drive activity

On = Drive activity

 

 

Flashing = High activity on the drive or drive is being configured as part of an array

 

 

Off = No drive activity

 

 

 

2

Online status

On = Drive is part of an array and is currently working

 

 

Flashing = Online activity

 

 

Off = No online activity

 

 

 