Table 13 | Quickfind diagnostic display LEDs |
| |
Item | Description | Status | Action |
|
|
|
|
7 | I/O power fault | Off = Normal | A power fault on the system I/O board occurred. If the |
|
| On = Attention required | problem persists, replace the system I/O board. |
|
|
|
|
8 | Therm trip | Off = Normal | The server experienced a thermal shutdown. |
|
| On = Attention required | If one of the CPU thermal LEDs is amber, that CPU |
|
|
| experienced an overtemperature condition. |
|
|
| Be sure that the processor heatsink is properly attached. For |
|
|
| more information, see Chapter 5, “Troubleshooting.” |
|
|
| Be sure that no |
|
|
| airflow across the processor heatsink. |
|
|
| Be sure that the correct DIMMs (1.2 inches tall) are installed. |
|
|
| Be sure that all fans are installed and working properly. |
|
|
|
|
9 | SCSI interlock | Off = Normal | Be sure that the SCSI backplane is installed properly. |
|
| On = Attention required |
|
|
|
|
|
10 | Power supply 1 | Off = Normal | Look at the LEDs on the front of the power supply and take |
|
| On = Attention required | the appropriate action. |
|
|
|
|
11 | Power supply 2 | Off = Normal | Look at the LEDs on the front of the power supply and take |
|
| On = Attention required | the appropriate action. |
|
|
|
|
12 | Bus error | Off = Normal | A bus error occurred. |
|
| On = Attention required | The error might have been caused by one of the adapter |
|
|
| cards on this bus (see amber LEDs for which slots might have |
caused the error).
If problem persists, remove or replace one or both of the cards.
Hot-plug SCSI hard drives
Figure 56 Hot-plug SCSI hard drive LEDs
Table 14 | ||
Item | Description | Status |
|
|
|
1 | Drive activity | On = Drive activity |
|
| Flashing = High activity on the drive or drive is being configured as part of an array |
|
| Off = No drive activity |
|
|
|
2 | Online status | On = Drive is part of an array and is currently working |
|
| Flashing = Online activity |
|
| Off = No online activity |
|
|
|
Server component identification 61