QuickFind diagnostic display board and lightpipe
To remove the QuickFind diagnostic display board and lightpipe:
1.Power down the server. See “Powering down the server” earlier in this chapter.
2.Extend the server from the rack. See “Extending the server from the rack” earlier in this chapter.
3.Remove the access panel. See “Removing the access panel” earlier in this chapter.
4.Remove the processor memory boards. See “Processor memory boards” earlier in this chapter.
5.Remove the
6.Remove the SCSI cables. See “SCSI cables” earlier in this chapter.
7.Remove the front fan cage. See “Front fan cage” earlier in this chapter.
8.Remove the
9.Eject all devices from the universal media drive bays. See “Universal media drives” earlier in this chapter.
10.Unplug the Power button/LED cable. See “Power button/LED assembly” earlier in this chapter.
11.Loosen the two thumbscrews holding the diagnostic display board.
12.Slide the board to the rear of the unit until it stops, and then lift it up.