Seagate DL585 manual Bbwce

Models: DL585

1 86
Download 86 pages 32.8 Kb
Page 67
Image 67

BBWCE

Figure 61 BBWCE LEDs

NOTE: The battery takes 24 hours to charge for the first time.

Table 21 BBWCE LEDs

Server status

LED color

LED status

Battery module status

 

 

 

 

Server is on and has normal

Green (2)

On

Fast charging

run time.

 

 

 

 

 

 

 

Green (2)

Off

Trickle charging

 

 

 

 

Amber (1)

On

Short in the connection of one

 

 

 

or more of the four button

 

 

 

cells within the battery module

 

 

 

 

Amber (1)

Blinking

Open in the circuit between

 

 

 

the positive and negative

 

 

 

terminals of the battery

 

 

 

module

 

 

 

 

Amber (1)

Off

Battery module status is

 

 

 

normal

 

 

 

 

Server is on and is in the first

Amber (1) or green (2)

On

Temporary lock-out state. Data

30 seconds after power up.

 

 

is lost because cable being

 

 

 

detached

 

 

 

 

Server is off and is in data

Amber (1)

Blinking every 15 seconds

Backing up user data held in

retention mode.

 

 

write cache.

CAUTION: After the server is powered down, wait 15 seconds and then check the LED illumination pattern before unplugging the cable from the battery module. The LEDs are not visible with the rear access panel on.

If the amber LED blinks after 15 seconds, do not remove the cable from the battery module. This module is backing up data, and data is lost if the cable is detached.

When the server is on, review the POST message before plugging or unplugging the cable from the module.