Temperature Control

The following are three conditions for heater control.

(1) Preset temperature maintaining condition

Function:

To heat the paper for reduction of ink dry time,

 

improvement of ink fixing, and paper winkles

 

protection.

Status:

Status of maintaining the heater temperature at

 

preset temperature.

Conditions:

(1) In case the heater is turned ON on the heater

 

control panel and the heater ON command

 

is received from the engine control board.

(2)In case the status is the same as the (1)’s and the status until the specified delay time after receiving the heater OFF command.

(3)In case of heater test.

(2)Standby temperature maintaining condition

Function:

To shorten time reaching the preset temperature

 

at print start.

Status:

Status of maintaining the heater temperature at the

 

specified standby temperature (35 °C) for

 

all heaters.

 

When the preset temperature is lower than the

 

specified stand by temperature (35 °C), the printer

 

maintaines the preset temperature.

Condition:

In case of time specified as the standby time after

 

completion of the preset temperature maintaining

 

condition.

4-2

Page 154
Image 154