4 Tighten the head fixing screws (2 pieces).

NOTE

-When changing the height of the head, tighten the head fixing screws while pushing the head down softly with your hand.

-When the head height is changed, change head height setting (19) in ENTER menu.

-When the head height is changed, print gap may be occurred at reciprocating print. In that case, adjust the correction value for reciprocating print. (See (20) Reciprocating print position (Left) adjustment value, and (21) Reciprocating print position (Right) adjustment value in ENTRY nemu.)