INSTALLATION INSTRUCTIONS

1.Remove all packing materials from the oven cavity, (do not remove the waveguide cover), and the feature sticker from the outside of the door, if there is one. Check the unit for any damage, such as a misaligned door, damaged door seals around the door or dents inside the oven cavity or on the door. If there is any damage, please do not operate the oven until it has been checked by a SERVICE CENTRE APPROVED BY SHARP and repaired, if necessary.

2.Accessories provided

1) Turntable 2) Low rack 3) High rack 4) Combined operation manual and cookbook

3.Since the door may become hot during cooking, you should place or mount the oven so that the bottom of the oven is 85 cm or more above floor. You should also keep children away from the door to prevent them burning themselves.

This oven is designed to be used on a countertop, in a cabinet or built-in. It should not be installed in any area where excessive heat and steam are generated, for example, next to a conventional oven unit. The oven should be installed so as not to block ventilation openings.

For R-890N(S)/(W): Allow a space of at least 40cm on the top, 5cm on both sides and at the rear of the oven for adequate air circulation. When installing in a cabinet, the minimum inside dimension of the cabinet should be 620mm(W) x 709mm(H) x 536mm(D).

When building the oven into a cabinet or wall, a Sharp built-in kit model number EBR-47ST for R-890N(S) and EBR-5000(W) for R-890N(W) are available which enable the microwave oven to be integrated within a kitchen, the kits are available from your retailer. Read carefully the installation instructions for the built- in kit before installation. This built-in kit has been tested according to Australian Standards. Sharp does not recommend the use of any other built-in kit.

If the oven is to be positioned near a conventional oven, ensure that adequate space is allowed, and a suitable heat shield is incorporated between the two to prevent damage to the oven and the built-in kit caused by heat. WARNING: The electrical outlet must be readily accessible so that the unit can be unplugged easily in

an emergency.

4.Neither the manufacturer nor the distributors can accept any liability for damage to the machine or personal injury for failure to observe the correct electrical connecting procedure.

The A.C. voltage must be single phase 230-240V, 50Hz.

5.This appliance must be earthed.

6.Operate the oven from a general purpose domestic outlet. If a generator is used, do not operate the oven with non-sinusoidal outputs.

7.Before using top or bottom heater for the first time, operate the oven without food for 20 minutes using both heaters. This will allow the oil that is used for rust protection to be burned off.

4

Page 7
Image 7
Sharp R-890N operation manual Installation Instructions