70 Appendix
Replacing the battery
Caution:
Be sure to carry out the following procedure when you replace the battery.
Otherwise all data and settings may be lost.
Turn off the SL-5500 and set the battery replacement switch to “REPLACE
BATTERY” before replacing the battery.
Connect the AC adapter when replacing the battery.
If you change the battery without connecting the AC adapter, replace the
battery within 5 minutes when the back-up battery is fully charged.
Only use the “EA-BL06” rechargeable battery.
1.
Slide the battery replacement switch on the rear side of the unit to the
“REPLACE BATTERY” position.
2.
Open the battery compartment lid.
3.
Remove the battery by gently pulling up the ribbon tab.
4.
Insert a new battery.
5.
Replace the battery compartment lid using the ribbon tab inside.
Caution: Be sure to replace the battery compartment lid.
6.
Slide the battery replacement switch to the “NORMAL OPERATION” position.
7.
Charge the battery.
About the back-up battery
The SL-5500 has a specified built-in rechargeable back-up battery which
prevents the memory contents from being erased when you replace the battery.
The rechargeable back-up battery will be charged to its full capacity in 30
hours under normal use in the following instances:
– When the AC adapter is connected;
– When the fully charged operating battery (EA-BL06) is inserted.
The rechargeable back-up battery will be exhausted if you leave an already
exhausted operating battery in the SL-5500 for more than a day, or when you
replace the operating battery.
The rechargeable back-up battery (when fully charged) keeps data stored in
the SL-5500 for approximately 5 minutes when the operating battery is not
inserted.
00 Cover.book Page 70 Saturday, January 19, 2002 11:33 AM