Displaying Time Data and Operation Mode Indications

Time data and operation mode indications can be displayed on the monitor screen.

Time data can also be displayed in the time counter display on this unit.

To view time data and operation mode indications on the monitor screen

Set the CHARA. DISPLAY menu item (see page 66) to ON (factory default setting).

The time data and the indication of the current operation mode are superimposed on the video signal that is being output from the SUPER connector, and can be viewed on the monitor screen.

Use the DISPLAY CONTROL menu items (see page 66) to select the information displayed and the character type and position of the indications.

When you set the SUB STATUS menu item (see page 67) to other than OFF, you can also display supplementary status information on the monitor screen such as the operating mode of the internal time code generator.

For details of supplementary status information, see “Displaying Supplementary Status Information” on page 79.

Monitor screen contents

The contents of the monitor screen are shown below.

ATime data type

Time data

 

 

 

 

 

 

 

 

 

 

 

 

BDrop frame indication

 

 

 

 

 

 

 

 

 

 

 

 

 

for time code reader a)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CDrop frame indication for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

time code generator a)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DVITC field

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

indication

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T

C

R

 

 

0

0

:

0

4

.

4

7

.

0

7

*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P

L

A

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F Recording indications during simultaneous playback and recording

EDSR-DR1000/DR1000P operation mode

a)This character (.) can appear on the DSR-DR1000 only. The character to appear in these two columns is always a colon ( : ) on the DSR-DR1000P.

ATime data type

The following time data type indications are displayed.

Indication

Description

 

 

CNT

Count value of the time counter

 

 

TCR

Time code data from time code reader

 

(factory default setting)

 

 

UBR

User bit data from time code reader

 

 

TCR.

Time code data from VITC reader a)

UBR.

User bit data from VITC reader a)

TCG

Time code data from time code generator

 

 

UBG

User bit data from time code generator

 

 

T*R b)

Time code data from time code reader. The

 

asterisk indicates an interpolation by the time

 

code reader to make up for the time code

 

data not correctly read from the disk.

 

 

U*R b)

User bit data from the time code reader. The

 

asterisk indicates that last data is retained by

 

the time code reader, as the new data has

 

not been read correctly from the disk.

 

 

a)You can switch between TC and VITC using the TC SELECT menu item (see page 68).

b)“*” is displayed when data cannot be read in correctly.

BDrop frame indication for time code reader (on DSR-DR1000 only)

.

Drop frame mode (factory default setting)

:Non-drop frame mode

CDrop frame indication for time code generator (for DSR-DR1000 only)

.

Drop frame mode (factory default setting)

:Non-drop frame mode

DVITC field indication

(blank)

Display fields 1 and 3.

*Display fields 2 and 4.

EDSR-DR1000/DR1000P operation mode

Display

Operation mode

 

 

STOP

Stop mode

 

 

F. FWD

Fast forward mode

 

 

REW

Rewind mode

 

 

PREROLL

Preroll mode

 

 

PLAY

Playback mode (servo unlocked)

 

 

PLAY-PAUSE

Temporary stop of playback

 

 

PLAY LOCK

Playback mode (servo locked)

 

 

REC

Record mode (servo unlocked)

 

 

28 Setting the Time Data