factory default settings. Wait until the saving is completed before powering off the unit.

To cancel the resetting operation

Instead of pressing the SET button, press the RESET button. The display returns to menu level 1, leaving the settings unchanged.

Displaying

Supplementary Status

Information

When you set the SUB STATUS menu item (see page 67) to other than OFF, you can view supplementary status information on the monitor screen below the operating mode display area.

T C R 0 0 : 0 4 . 4 7 . 0 7

P L A Y

L O C K

M I X E D T U V

Supplementary status information

The following items of supplementary status information are displayed depending on the setting of the SUB STATUS menu item.

Setting of SUB

Items of supplementary

STATUS menu item

information displayed

 

 

TC MODE

Operating mode of the internal time

 

code generator

 

 

REMAIN

Remaining capacity of the disk

 

 

CLIP NAME

Clip name

 

 

AUDIO MIXING

Setting for input audio mixing

 

 

ALL

All of the above items

 

 

The following tables show the on-screen indications of supplementary information and their meaning.

In each table, the indications given in brackets such as [ASM] are the indications displayed when the SUB STATUS menu item is set to ALL.

For the display format when ALL is selected, see the next section.

When the SUB STATUS menu item is set to TC MODE:

On-screen

Meaning

indication

 

 

 

INT PRST FREE

The internal time code generator is

[IP F]

operating in FREE RUN mode.

 

 

INT PRST REC

The internal time code generator is

[IP R]

operating in REC RUN mode.

 

 

INT REGEN-T&U

The internal time code generator is in

[IRTU]

synchronization with the playback

 

time code (LTC) read from tape.

 

 

Displaying Supplementary Status Information

79