Set the F-RUN/SET/R-RUN switch to R-RUN. Set the DISPLAY switch to CTL.

6 Set the iris back to automatic adjustment mode, and check the following points when the GAIN selector is moved from L to M to H.

For objects of the same brightness, the iris is adjusted to correspond to the change in setting.

The gain indicator on the viewfinder screen changes to correspond to the change in setting.

7 If an extender mechanism is incorporated in your lens, put it into the operative position and check the effect.

6-1-3 Testing the VTR

Perform tests 1 to 6 consecutively in the given order.

6 1 Testing the tape transport functions

1 Set the VTR SAVE/STBY switch to SAVE and check that the VTR SAVE indicator in the viewfinder goes on.

2 Set the VTR SAVE/STBY switch to STBY and check that the VTR SAVE indicator in the viewfinder goes off.

3

4

5 Press the VTR START button and check the following points.

The tape reels are turning.

The counter indication is changing.

The REC indicator in the viewfinder is on.

The RF and SERVO indicators on the display panel are off.

6-6Chapter 6 Maintenance