If automatic white balance adjustment cannot be made If the white balance adjustment cannot be completed normally, an error message will appear for about 3 seconds on the viewfinder screen (in display mode 2 or 3).

Possible messages are listed below.

 

 

White balance adjustment error messages

 

 

Error message

Meaning

4

 

 

 

 

WHITE : NG

The white video level is too low. Either make

 

LOW LEVEL

open the lens iris or increase the gain.

 

 

WHITE : NG

The color temperature is too high. Select a

 

 

 

COLOR TEMP. HIGH

suitable filter setting.

 

 

WHITE : NG

The color temperature is too low. Select a

 

 

COLOR TEMP. LOW

suitable filter setting.

 

 

 

 

 

 

WHITE : NG

Adjustment could not be completed within the

 

 

TIME LIMIT

standard number of attempts.

 

 

 

 

 

 

WHITE : NG

The white area could not be checked.

 

 

POOR WHITE AREA

 

 

 

 

 

 

 

WHITE : NG

The white video level is too high. Either narrow

 

 

LEVEL TOO HIGH

the lens iris opening or change the ND filter.

 

 

 

 

If any of the above error messages is displayed, retry the white balance adjustment. If the error message occurs again, an internal check is necessary.

Refer to “maintenance manual” for information about this internal check.

4-10Chapter 4 Adjustments and Settings for Recording