1 Set the shutter speed mode to CLS.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CLS:60.3Hz

 

 

 

 

 

 

4

 

 

 

 

 

The value indicated differs between camcorder models.

 

 

CLEAR SCAN page (factory settings)

 

 

2 Turn the rotary encoder counterclockwise as seen from the front of

 

 

the camera to increase the value, or clockwise to decrease the value,

 

 

until the desired frequency appears.

 

 

The frequency ranges as follows.

 

 

DVW-707:

60.3

Hz to 10156 Hz in 261 steps

 

 

DVW-709WS:

60.1 Hz to 7000 Hz in 260 steps

 

 

DVW-790WS:

60.1

Hz to 7000 Hz in 260 steps, and

 

 

 

 

30.4

Hz to 58.3 Hz in 248 steps

 

 

DVW-707P:

50.0

Hz to 10101 Hz in 312 steps

 

 

DVW-709WSP:

50.2 Hz to 9000 Hz in 310 steps

 

 

DVW-790WSP:

50.2

Hz to 9000 Hz in 310 steps, and

 

 

 

 

25.4

Hz to 48.7 Hz in 295 steps

Pressing the MENU CANCEL/PRST/ITEM switch toward the CANCEL/PRST position returns the setting to the default value,

60.3Hz (DVW-707)/60.1 Hz (DVW-709WS/790WS) or

50.0Hz (DVW-707P)/50.2 Hz (DVW-709WSP/790WSP).