Press the k button.

To set the internal switch to on

1

DATA

DATA

DATA

DATA

VITC VIUB COUNTER VITC

ALARM

 

 

 

 

 

 

 

 

 

 

HOURS

MINUTES

SECONDS

FRAMES

 

 

 

 

AUDIO

625

IMX[50 40 30

]

 

 

 

 

48CH

16 24 BIT

525

DVCAM

 

CH- 15

CH- 26

CH- 37

CH- 48

BATT

E

 

 

F

 

12

SHUTTLEJOG

AUDIO MONITOR

L L

CH-1 CH-2 CH-3 CH-4 CH-5 CH-6 CH-7 CH-8

R R

ACCESS

NETWORK LOCAL REMOTE

SUB

CLIP THUMBNAIL MENU SET RESET SHIFT

Menus 7 Chapter

2

S1902, switch 4

1 Using a Phillips screwdriver, remove the bottom cover.

There are five screws fixing the cover.

2 Using a sharp implement such as a ball-point pen, set switch 4 in the S1902 group to the ON position (on the front side).

3 Replace the bottom cover.

Note

Tighten the screws firmly.

To enable extended menu display in the maintenance menu

Carry out the following operations.

 

CLIP

ESSENCE SYSTEM S.SEL

MARK1

 

MENU

MARK

MENU

 

PREV

PLAY

NEXT

STOP

 

 

 

 

IN

OUT

TOP F REV

F FWD END

MARK2

8 3,5,7 4,6

1 Press the MENU button.

The menu appears in the status display.

2 Hold down the COUNTER button, and press the SET button.

In the status display, first “MAINTE MENU” appears momentarily, and then the item group name appears.

3 Using the J/j buttons, display “Setup” in the status display.

4

5 Using the J/j buttons, display “> Extended” in the status display.

6 Press the k button.

The status display shows the current setting (“>> DISABLE”).

7 Press the j button, to display “>> ENABLE” in the status display.

76 7-3 Extended Menu