Southbend SB1014F specifications Additional Component Wiring, Additional com

Models: SB1014F

1 148
Download 148 pages 8.96 Kb
Page 106
Image 106

EVS Toolroom Lathes

E L E C T R I C A L

For Machines Mfg. Since 8/09

Additional Component Wiring

Spindle

RPM Sensor

Door Limit

Switch

Fig. 11. RPM sensor and door limit switch location.

Brake Limit

Switch

Fig. 12. Brake limit switch location.

Chuck

Guard Limit

Switch

Fig. 13. Chuck guard limit switch.

8

Work Light

 

additional com-

 

pontnet

Wt

 

 

Bk 2

 

 

0

Door Limit

 

 

Switch, Figure 11.

 

 

COMMON

 

 

?

 

 

NO

Bk

0

NC

 

1X

Wt

 

Spindle RPM Sensor, Figure 11.

 

COM

 

 

KX

B

 

L

 

Chuck Guard Limit Switch, Figure 13.

 

3

 

9X

NC

NO

 

A

A1

4

 

NC

NO

Brake Limit Switch, Figure 12.

5X

14

13

A1

 

@

 

 

3

22

21

6

To Electrical

Box, Page 7.