■ DIP switch 1 | Factory presetting: All ON*1 | |||
|
|
|
| |
SW | Function | ON | OFF | |
|
|
|
| |
Not used | (Always ON) | |||
|
|
|
| |
Hand shaking (BUSY condition) | Receive buffer | Recive | ||
full or offline | buffer full | |||
|
| |||
|
|
|
| |
Always ON | Should be set on | |||
|
|
|
| |
Auto Cutter *1 | Invalid | Valid | ||
|
|
|
| |
Printing width *2 | 210 dots | 200 dots | ||
(420 half dots) | (400 half dots) | |||
|
| |||
|
|
|
| |
Automatic status function *3 | Invalid | Valid | ||
|
|
|
| |
Should not be change | (Should be set on) | |||
|
|
|
| |
Command emulation | Star | ESC/POS | ||
|
|
|
|
*1.The factory settings for enabling/disabling the
Note: If the
*2 Total dot number for one line.
(This setting determines the default print range and number of digits as follows.)
Switch | Print range | ANK default digits (ANK 7 ⋅ 9/5 ⋅ 9) |
|
|
|
ON | 63 mm | 42/35 digits |
|
|
|
OFF | 60 mm | 40/33 digits |
|
|
|
*3 Automatic status function: When valid, the status occurrence conditions are as follows.
Star mode: All status occurrences enabled.
ESC/POS mode: Online/offline factors only. (Same conditions as <GS>a2).
APPENDIX