■ DIP switch 1 | Factory presetting: All ON*1 | |||
  | 
  | 
  | 
  | |
SW  | Function | ON  | OFF | |
  | 
  | 
  | 
  | |
Not used  | (Always ON)  | |||
  | 
  | 
  | 
  | |
Hand shaking (BUSY condition)  | Receive buffer  | Recive  | ||
full or offline  | buffer full  | |||
  | 
  | |||
  | 
  | 
  | 
  | |
Always ON  | Should be set on  | |||
  | 
  | 
  | 
  | |
Auto Cutter *1  | Invalid  | Valid  | ||
  | 
  | 
  | 
  | |
Printing width *2  | 210 dots  | 200 dots  | ||
(420 half dots)  | (400 half dots)  | |||
  | 
  | |||
  | 
  | 
  | 
  | |
Automatic status function *3  | Invalid  | Valid  | ||
  | 
  | 
  | 
  | |
Should not be change  | (Should be set on)  | |||
  | 
  | 
  | 
  | |
Command emulation  | Star  | ESC/POS  | ||
  | 
  | 
  | 
  | |
*1.The factory settings for enabling/disabling the 
Note: If the 
*2 Total dot number for one line.
(This setting determines the default print range and number of digits as follows.)
Switch   | Print range  | ANK default digits (ANK 7 ⋅ 9/5 ⋅ 9)  | 
  | 
  | 
  | 
ON  | 63 mm  | 42/35 digits  | 
  | 
  | 
  | 
OFF | 60 mm  | 40/33 digits  | 
  | 
  | 
  | 
*3 Automatic status function: When valid, the status occurrence conditions are as follows.
Star mode: All status occurrences enabled.
ESC/POS mode: Online/offline factors only. (Same conditions as <GS>a2).