SSPET5
5.1. Maintenance intervals
Daily: | Check warning signs on equipment for good |
| legibility and completeness |
Weekly: | Check the maintanance unit |
| Check operating pressure of the plant’s supply |
| network |
Monthly: | Check function of the device plug |
| Check the sealings on the filter cartridges |
| (according to the accumulation of dust) |
Every 6 months: | Check all electrical and mechanical connections |
| for tight fit |
| Check the settings on the level probes (if present) |
| Check filter contamination, if necessary clean or |
| replace the filter cartridges |
Annually: | Replace outlet valve sealing |
| Adjust valve switch |
After 1000 |
|
operating hours: | Replace carbon brushes |
F
The given maintenance intervals are average values.
Check whether in your individual case the maintenance in- tervals must be shortened.