a.Loosen the four nuts that secure the rear bracket.

b.Reposition the rear bracket to the location marked “NGR Cabinet” on the slide rail assembly and secure the rear bracket.

3. Insert the pins in the front bracket into cabinet holes 22 and 33 (FIGURE 1-7).

Front bracket

Rear bracket

secured to outer cabinet holes

secured to outer cabinet holes

FIGURE 1-7Installing the Rails in a Sun Rack 900 Cabinet or 19-Inch Four-Post Cabinet

The pins will hold the bracket in place until the bracket is secured.

4.Secure the rear bracket into cabinet holes 24 and 31 with two M-6 UNF screws.

5.Secure the front bracket into cabinet holes 24 and 31 with two M-6 UNF screws.

6.Repeat Step 1 through Step 5 for the second slide rail assembly.

Note – Mounting the server in cabinet holes 24 and 31 allows for 10-inches of space beneath the server in order to service the backplane.

12 Netra 1290 Server Installation Guide • May 2006

Page 24
Image 24
Sun Microsystems 1290 manual Front bracket Rear bracket Secured to outer cabinet holes