Syntax and Commands
3-28 AFG3000 Series Arbitrary/Function Generators Reference Manual
MMEMory:LOAD:STATe (No Query Form)
This command copies a setup file in the mass storage system to an internal setup
memory. If a specified internal setup memory is locked, this command causes an
error.
When you power off the instrument, the setups are automatically overwritten in the
setup memory 0 (last setup memory).
Group Mass Memory
Related Commands MEMory:STATe:LOCK
MEMory:STATe:RECall:AUTo
MMEMory:STORe:STATe
Syntax MMEMory:LOAD:STATe{0|1|2|3|4},<file_name>
Arguments 0, 1, 2, 3, or 4 specifies the location of setup memory.
<file_name>::=<string> specifies a setup file to be copied.
Examples MMEMory:LOAD:STATe 1,SETUP1.TFS
copies a file named SETUP1.TFS in the mass storage into the internal memory
location 1.
MMEMory:LOAD:TRACe (No Query Form)
This command copies a waveform data file in the mass storage system to Edit
Memory. If the file format is different, this command causes an error.
Group Mass Memory
Related Commands MMEMory:STORe:TRACe
Syntax MMEMory:LOAD:TRACe EMEMory,<file_name>
Arguments <file_name>::=<string> specifies a waveform data file to be copied.
Examples MMEMory:LOAD:TRACe EMEMory,TEK001.TFW
copies a file named TEK001.TFW in the mass storage into Edit Memory.