Status and Events
AFG3000 Series Arbitrary/Function Generators Reference Manual 4-15
Device Specific Errors Table 4-8 lists the device-specific errors that can occur during arbitrary/function
generator operation. These errors may indicate that the instrument needs repair.
Query Errors Table 4-9 lists the error codes that are returned in response to an unanswered query.
Power-on Events These events occur when the instrument detects an off to on transition in its power
supply.
Table4-8: Device-specific error messages
Error code Message
–300 Device specific error
–310 System error
–311 Memory error
–312 PUD memory lost
–313 Calibration memory lost
–314 Save/recall memory lost
–315 Configuration memory lost
–320 Storage fault
–321 Out of memory
–330 Self-test failed
–340 Calibration failed
–350 Queue overflow
–360 Communication error
–361 Parity error in program message
–362 Framing error in program message
–363 Input buffer overrun
–365 Time out error
Table4-9: Query errors
Error codes Message
–400 query error
–410 query INTERRUPTED
–420 query UNTERMINATED
–430 query DEADLOCKED
–440 query UNTERMINATED after indefinite response
Table4-10: Power-on events
Event code Event message
–500 Power on