Syntax and Commands
AFG3000 Series Arbitrary/Function Generators Reference Manual 3-65
[SOURce[1|2]]:PM:STATe
This command enables or disables PM modulation. The query command returns
the state of PM modulation.You can select a sine, square, ramp, or arbitrary wave-
form for the carrier waveform.
Group Source
Syntax [SOURce[1|2]]:PM:STATe {ON|OFF|<NR1>}
[SOURce[1|2]]:PM:STATe?
Arguments ON or <NR1>0 enables PM modulation.
OFF or <NR1>=0 disables PM modulation.
Returns <NR1>
Examples SOURce1:PM:STATe ON
enables the CH 1 PM modulation.