Appendix B: Automatic Measurements Reference

B-22 CSA8000B & TDS8000B User Manual

Table B- 4: RZ Measurements - Amplitude (cont.)
Name Definition
RZ Min The minimum vertical value of the waveform that is sampled within the measurement region.
If enabled, measurement gates constrain the measurement region to the area between the Start
Gate (G1) and Stop Gate (G2).
When this measurement is turned on, it will automatically set the measurement system to use a
waveform database if available.
For best results with this measurement:
HPerform a Dark Level compensation before taking this measurement if the source of the
measured waveform is an optical channel. See To Perform Dark-Level and User
Wavelength Gain Compensations on page 3--98.
HOptimize the vertical resolution before taking this measurement. See To Optimize the
Vertical Resolution on page B--69.
RZ Peak-to-Peak The difference between the Max and Min vertical values of the waveform that is sampled within
the measurement region.
RZ Peak-to-Peak = Max Min
Where Max and Min are the maximum and minimum measurements.
If enabled, measurement gates constrain the measurement region to the area between the Start
Gate (G1) and Stop Gate (G2). See To Localize a Measurement on page 3--83.
When this measurement is turned on, it will automatically set the measurement system to use a
waveform database if available. See Use a Waveform Database on page B--70.
For best results with this measurement:
HPerform a Dark Level compensation before taking this measurement if the source of the
measured waveform is an optical channel. See To Perform Dark-Level and User
Wavelength Gain Compensations on page 3--98.
HOptimize the vertical resolution before taking this measurement. See How to Optimize the
Vertical Resolution on page B--70.